100,000,000+ Carts Filled Globally

Categories
Events General

MJBizCon 2021: Vape-Jet Has Entered the Game

Two years ago our exec team showed up to MJBizCon 2019 in our signature hoodies with brochures in their pockets and high hopes. They networked while walking the expo floor and met with potential partners and customers offsite to establish working relationships and promote the only machine we had in production at that time; the Vape-Jet 2.0 fully-automatic filling machine.


Fast forward two years through a vaping crisis and a global pandemic to MJBizCon 2021. This year our team arrived on the expo floor with a dedicated booth, a new semi-automatic filling machine (Jet Fueler 2.0), an upgraded fully-automatic filling machine (Vape-Jet 3.0), a brand new automatic capping machine (Squish-o-Matic 1000), and our same signature hoodies. (Plus a few gold doge coins in our pockets.)

Vape-Jet Exec Team 2019 and 2021: Brian Kuo – CFO, Ryan Hoitt – CEO, Devon Reid – COO
Standard Currency at Vape-Jet

This year our crew was able to connect with hundreds of attendees looking for affordable automation solutions in the face of a nationwide labor shortage, economic inflation, and supply chain disruptions. Those we spoke to were looking for solutions to their production challenges that provided low labor costs, increased workflow efficiency, and allowed them to adapt to different cartridge types as the availability of their usual hardware has become less reliable in recent months. At Vape-Jet we pride ourselves on our ability to innovate, adapt and evolve to meet the changing needs of our customers. All traits that have become increasingly important during a period where “unprecedented times” have become the norm.

Devon Reid Talking Through the Benefits of the Machine Vision Feature of the Vape-Jet Fully-Automatic Filling Machine
Vape-Jet Booth and a Visit from Nate with

As we’ve grown as a company, we’ve expanded our network of partners.

Amongst these are brands like Arcane Aromatics, a new-to-market supplier offering botanical terpene blends, hemp botanical extracts, and hemp + botanical terpene blends available at prices you won’t find elsewhere. If you visited our booth at the convention, you likely would have picked up on the scent of Arcane’s samples before you even saw our team as these aromatic creations were impossible to miss. Visit ArcaneAromatics.com to learn more about their pre-launch catalog and get early access to their product line. (Pro Tip: Arcane offers partner pricing for current and new Vape-Jet customers for orders of 60mL through 1L.)

Grant of Arcane Aromatics Discussing Their Pre-Launch Catalog
A Peek at Arcane Aromatics’ Botanical Terpene Blends

Also on display at MJBizCon were products from Advanced Vapor Devices (AVD) who produce a variety of the highest quality vape hardware. All AVD products work seamlessly with the Vape-Jet and Jet Fueler filling machines, as well as the Squish-o-Matic 1000 capping machine. For oil brands and processors AVD offers a test hardware kit that includes cartridges, disposables and batteries at no cost. Learn more at AVD710.com.

Vape-Jet 3.0 Demoing Dry Runs with AVD Cartridges
The AVD Social Media Team Stopped by for a Quick Interview with CEO Ryan Hoitt

Another excellent hardware manufacturing partner present on the expo floor was the team at BeGreen Supply. They offer custom engineered and branded cannabis hardware and packaging solutions that can be filled with our automatic filling machines. BeGreen shares the Vape-Jet perspective that your brand “deserves the ability to react to shifts in market and customer demand” and offer custom branded hardware in 30 days or less allowing production to stay agile and flexible. Learn more at BeGreenSupply.com

The Jet Fueler 2.0 and a Variety of Compatible Cartridges Including BeGreen Supply

In addition to our partners in manufacturing and suppliers our team met with several current customers who had great feedback on their experience with our products. Recently our customer Alex of Dime Industries (CA) told us “The Jet Fueler speaks for itself. There’s not another machine on the market that will last a million fills with no maintenance.”

The Jet Fueler 2.0 Demo Unit on Display
A Variety of Compatible Cartridges by AVD, Ilo and More

If you stopped by our booth during the show you may have met another one of our customers, James of Natural Roots Extracts (OR) who remains one of our most loyal customers having used every variation of our machines from Vape-Jet 1.0 and Jet Fueler 1.0 up to our latest iterations. He was also one of the original test users of our new automatic capping machine and is credited with coming up with the official name, Squish-o-Matic 1000. James recently said “The Vape-Jet 3.0 has really blown my mind. The improvement to our workflow has been literally life-changing.” We’re glad he was able to attend the show and share his experience and expertise with anyone interested in our filling and capping solutions.

James of Natural Roots Extracts Discussing Cartridge Styles
James’ Vape-Jet 3.0 Unit Performing Dry Runs During the Show

All in all MJBizCon 2021 was a major success for the Vape-Jet team and a clear reflection of how far we have grown since hitting the expo floor in 2019. Thank you to everyone on the team who made this show possible. We’ll see you all again in 2022!

The Vape-Jet Booth
Brian Kuo – CFO, Ryan Hoitt – CEO, Sawyer Sheppard – Sales Rep
Two Legends Meet: Tommy Chong and Brian Kuo
Squish-o-Matic 1000 on Display
Until next year!
Categories
General Laboratory

Laboratory Technique – Rotary Evaporator Optimization

This article explains the general process to achieve the maximum possible solvent recovery rate from any rotary evaporator.

Introduction

Rotary evaporation is a powerful technique for quickly removing solvent from a solution of cannabis or hemp extract. There are two distinct methods of operating a rotary evaporator: batch or continuous; choosing the correct one for the task is crucial. For the purposes typically required in the cannabis industry, i.e. winterization or color remediation of extracts, the necessary volume of solvent to be recovered invariably necessitates a continuous style of operation for rotary evaporators. Not only can solvent recovery rates be increased by 2-4x with this mode of operation, but overall throughput is increased as well since vacuum is maintained until the rotary flask (or solvent recovery flask) is ready to be emptied. 

Continuous Operation

In order to achieve the highest possible solvent recovery rate, several individual rates of the rotary evaporation process must be tuned to match or complement each other. The defining characteristic of continuous operation is the slow and constant addition of fresh solution into the rotary flask. Only as much solvent as can be evaporated and condensed should be added to the rotary flask per unit of time. In other words, the volume solvent dripping off the condenser should be equal to the volume of solvent containing solution dripping into the rotary flask.

Important Constants:

  1. Heat – the water bath provides heat to the evaporating surface of the rotary flask. Having enough hot water to cover a large area of the rotary flask is essential.
  2. Vacuum – the vacuum in the system can be thought of as essentially constant if the pump is of sufficient capacity. Having a large enough vacuum pump is vital.
  3. Cold – the condenser removes heat from the vapor and forces it to drip into the collection flask. Having a high cooling capacity is the most important factor.

These important constants are listed in order of increasing difficulty and cost to achieve. Heating water is a very easy and low cost part of the system, the vacuum pump is more specialized but relatively simple, while the refrigeration unit is the most complex and costly component. Having insufficient cooling capacity will dramatically decrease the maximum rate of solvent recovery possible from any rotary evaporation system.

The greater the difference in temperature (ΔT) between the hot (evaporation) and cold (condensation) sides of the system, the faster the solvent can be recovered.  

Ideally, the refrigeration unit of the rotary evaporator system will be large enough so that ΔT behaves as a constant during operation at maximum recovery; in reality, the refrigeration fluid will become hotter as evaporation and condensation begin, until it settles at its operating temperature. As the proportion of extract in the boiling flask increases and solvent decreases, the rate of evaporation will also decrease, resulting in a lower refrigerant temperature.

Important Rates:

Keeping the constants in mind, there are several factors which must be tuned in order to achieve maximum recovery. The ΔT for each system is unique and largely dependent upon the refrigeration unit, tuning the following rates to keep ΔT from changing is the essence of continuous operation of a rotary evaporator.

  1. Rotation – the rate at which solution is exposed to warm surface area to evaporate.
  2. Feed – the rate of addition of fresh solution into the boiling flask, limited by the rate of Evaporation. 
  3. Evaporation – how fast solvent transforms from liquid to gas, determined as a function of Rotation and Feed, in combination with Heat and Vacuum.
  4. Condensation – how fast solvent transforms from gas to liquid, determined as a function of Cooling and Vacuum.

In order to achieve maximum solvent recovery, the operator must tune Rotation and Feed rates such that Evaporation and Condensation rates become equal with the highest possible ΔT.

Example

  1. Attach a length of food-grade tubing to both sides of the Feed Valve.
    1. The rotary flask side of tubing should extend beyond the neck and slightly down the bulb, this reduces splash.
    2. The external side of tubing should be long enough to reach the bottom of the beaker or flask that contains your solution of extract and solvent (i.e. ethanol).
    3. Let your solution come to room temperature prior to solvent recovery, if possible. 
  2. Heat the water bath to at least 60C.
    1. Ensure there is enough water to come up almost to the level of the rotary flask neck, covering 30-40% of the flask when fully lowered.
  3. Turn on the refrigeration unit to its lowest possible setting, below 0C is ideal.
  4. Turn on the vacuum pump.
  5. Set flask rotation to about 100 revolutions per minute (RPM).
  6. Once the refrigerator and vacuum are as low as they can be, flask rotating, and with the external tubing in your solution containing beaker, slowly open the Feed Valve.
    1. Adjust feed valve to a very fine trickle, such that a band of extract forms immediately on the inner surface of the rotating flask.
    2. If a puddle forms or grows within the first few minutes, close the Feed Valve slightly.
    3. A puddle of extract rich solution will begin to form after several minutes, adjust RPM as needed to keep the puddle at the bottom of the flask.
    4. If the puddle is too rich in extract, the Feed Rate can be increased; if the puddle is too rich in solvent, decrease the Feed Rate.
  7. Monitor the refrigerator temperature throughout and adjust the Feed Valve accordingly, i.e. reduce Feed if temperature increases.
  8. Once the rotary flask approaches 30-50% full of extract rich solution, the Recovery Rate will decrease.
    1. Close Feed Valve to reduce chance of boil over, and continue rotary evaporation on the solution in the rotary flask until the desired level of completion.
  9. Remove and collect the extract from the rotary flask as normal with heat, gravity, and silicone scrapers.

We use cookies to improve our user experience. By using our site, you consent to the use of cookies. Read More